-Plate&Shell-® Heat Exchanger

Vahterus PSHE combines the benefits of Plate & Frame and Shell & Tube heat exchangers. PSHE can either be described as a fully welded, high integrity plate heat exchanger, with no gaskets; or a generic alternative to Shell & Tube, approx. 25% of the footprint, displaying both space and weight benefits.

Benefits of PSHE -

• No Gaskets or Brazing
• High Integrity / Total Containment
• Strong and Safe Construction
• Unique Protection and Resistance
  to Thermal and Pressure Cycling
• Thermally Efficient
• Compact and Low Weight
• Flexible Construction
• Proven, Reliable Technology
• Low Fouling
• Minimal Maintenance Requirement
• Close Approach Temperatures

The -Plate&Shell-® Heat Exchanger is the first of a new generation of heat exchangers developed by Vahterus. At the heart of the PSHE is a fully welded pack of circular plates which is housed within an outer pressure vessel. The PSHE combines the best features of PHE and shell & tube exchangers offering a durable, compact and gasket free solution with high heat transfer, high pressure and high temperature capability. -

The -Plate&Shell-® Openable version offers increased flexibility of use by allowing the fully welded platepack to be completely withdrawn from the shell for inspection or cleaning. This is achieved by the use of a flanged and bolted shell construction. The cassette type platepack allows quick and easy removal and refitting thus ensuring that process downtime is kept to a minimum. -

The -Plate&Shell-® Compact exchanger has been developed by Vahterus to offer an even more compact unit than the standard PSHE construction. By using a clever system of internal flow directors, it is possible to have all 4 primary and secondary fluid connections on one end of the unit, which significantly reduces the required space.

Vahterus PSHE can be used in many applications, in each instance offering space and weight benefits over traditional shell & tube exchangers:

  • Liquid/ liquid
  • Liquid/Gas
  • Gas/Gas
  • Condensers
  • Evaporators
  • Cascades
  • Multi-Phase / Multi-Component Systems

    Technical Specification

    Maximum Heat Transfer Area
    • 2000 m²/ exchanger

    Mechanical Design
    • Full vacuum to 150 bar possible
    • -200 to +900 °C

    Main data:

      Area/plate, m²  Plate side nozzles, DN Shell side nozzles, DN
    PSHE 2 0.032 25 20-80
    PSHE 3 0.076 50 25-250
    PSHE 4 0.15 80 25-300
    PSHE 5 0.26  100 25-350
    PSHE 6 0.356 125 25-500
    PSHE 7 0.46 150 25-500
    PSHE 9 0.80 200 25-700
    PSHE 14 1.55 300 25-1000
    PRHE 12 1.00 200 25-1000